Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
RGO (Porto Alegre) ; 61(3): 363-367, jul.-set. 2013. tab, ilus, graf
Artigo em Inglês | LILACS | ID: lil-691752

RESUMO

Objective: To compare he influence of two activation modes on two similar dual-polymerized resin cements. Methods: Bars (2 × 2 × 12 mm) of RelyX ARC (3M ESPE, MN, USA) (ARC) and Enforce (Dentsply, Rio de Janeiro, Brazil) (ENF) were prepared, and three types of polymerization method were tested: (1) L: LED photoactivation/40 s; (2) H: halogen Light activations/40 s, and (3) C: chemical activation only (Complete absent of light). The groups were ARC-L; ARC-H, ARC-C, Enf-L, Enf-H, and Enf-C (n = 8). After 24 h, the specimens were tested using the 3-point bending method on a universal testing machine. Results: The ARC cement showed superior flexural strength results. The mode of activation revealed similar results on both cements tested, but lightactivated groups (with LED or Halogen light) showed higher flexural strength values than did the chemical-activation-only group. Conclusion: (1) RelyX ARC cement showed superior flexural strength when compared with Enforce; and (2) light activation resulted in better flexural strength values when compared to chemical activation on dual-polymerized resin cements.


Objetivo: Comparar a influência do modo de ativação de dois cimentos semelhantes, porém de fabricantes distintos. Métodos: Barras (2 x 2 x 12 mm) dos cimentos RelyX ARC (3M ESPE, MN, USA) e Enforce (Dentsply, Rio de Janeiro, Brasil) (ENF) foram confeccionadas com auxílio de uma matriz de teflon bipartida, e três modos de fotopolimerização foram testados: (1) L: fotoativação por LED / 40 segundos; (2) H - fotoativação por luz halógena / 40 segundos; e (3) Q - apenas ativação química (ausência total de luz). Os grupos formados foram: ARC-L; ARC-H; ARC-Q; Enf-L; Enf-H e Enf-Q, com 8 amostras cada. Após 24 horas, o teste de miniflexão de três pontos foi aplicado em máquina universal de testes. Resultados: O cimento ARC apresentou resultados de resistência superiores ao cimento Enf. O modo de ativação agiu de forma semelhante nos dois cimentos testados, sendo que a ativação por luz, seja L ou H, aumentou a resistência para ambos, comparada a ativação Q. Conclusão: (1) O cimento RelyX ARC (3M ESPE, MN, USA) apresentou maior resistência à flexão de três pontos quando comparado ao cimento Enforce(Dentsply, Rio de Janeiro, Brasil); e (2) a ativação por luz aumentou a resistência para cimentos resinosos duais.


Assuntos
Autocura de Resinas Dentárias , Cimentos de Resina , Ciência dos Materiais
2.
RGO (Porto Alegre) ; 61(1): 41-46, abr.-jun. 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-874811

RESUMO

Objective: The aim of this study was to evaluate the erosive effect of three beverages which are considered to be acidic in vitro study.Methods: We used 45 third molars. The teeth were cut to obtain 90 4x4 mm enamel blocks, obtained from the buccal and lingual surfaces of each tooth. The groups were divided by type of beverage (Coca-Cola®, Coca-Cola do Brasil, Rio de Janeiro, Brazil; Coca-Cola Zero®, Coca-Cola do Brasil, Rio de Janeiro, Brazil and Gatorade uva®, Ambev, Jaguariúna, Brazil) and number of cycles (7, 15 and 30 cycles). For each cycle, the specimens were immersed in the drink for 2.5 minutes by alternating with immersion in saliva for 1 hour. Each cycle simulates one day of intake. Statistical analysis, ANOVA and Tukey 5% for profilometry showed the statistical difference between the kind of beverages and between periods.Results: Coca-Cola® (Coca-Cola do Brasil, Rio de Janeiro, Brazil) (3.99±1.25) differed from other kinds of beverage. All the periods differed and the period of 30 days saw the greatest structural loss. For microhardness, the statistical analysis showed greater loss of surface hardness for the group Coca-Cola® (Coca-Cola do Brasil, Rio de Janeiro, Brazil) within 30 days (126.02 ± 30.98) SHL. Conclusion: IIt was concluded that the soft drink Coca Cola® (Coca-Cola do Brasil, Rio de Janeiro, Brazil) had the greatest erosive effects and the higher the number of cycles the greater the influence on the process of dental erosion.


Objetivo: Avaliar o efeito erosivo de três bebidas ácidas sobre o esmalte dentário num estudo in vitro. Métodos: Foram utilizados 45 terceiros molares humanos. Noventa blocos de esmalte de dente humano (4X4 mm) foram obtidos a partir das faces vestibular e lingual de terceiros molares. Os blocos de esmalte foram divididos de acordo com o tipo de bebida testada (Coca-Cola®, Coca-Cola do Brasil, Rio de Janeiro, Brasil; Coca-Cola Zero®, Coca-Cola do Brasil, Rio de Janeiro, Brasil e Gatorade uva®, Ambev, Jaguariúna, Brasil) e quantidade de ciclos (7, 15 e 30 ciclos). Cada ciclo simulava um dia de ingestão, o qual compreendia a imersão dos corpos de prova (n=10/tipo de bebida e quantidade de ciclos) nas bebidas (2,5 minutos), alternados por imersão em saliva (1 hora). Para quantificação do efeito erosivo, foi avaliada a perfilometria (?m±DP) e a perda de dureza superficial. Os dados foram analisados por ANOVA 2 fatores e Tukey 5%. Resultados: A perfilometria demonstrou diferença estatística entre as bebidas e entre os períodos, sendo que a Coca-Cola® (Coca-Cola do Brasil, Rio de Janeiro, Brasil) (3.99±1,25) diferiu das outras bebidas. Todos os períodos diferiram entre si sendo que para o período de 30 dias ocorreu a maior perda de estrutura. Para a microdureza a análise estatística demonstrou maior perda de dureza superficial para o grupo Coca-Cola® (Coca-Cola do Brasil, Rio de Janeiro, Brasil) no período de 30 dias (126,02 ± 30,98) perda de dureza superficial. Conclusão: Concluiu-se que a Coca-Cola® (Coca-Cola do Brasil, Rio de Janeiro, Brasil) apresentou os maiores efeitos erosivos e quanto maior número de ciclos, maior a influência no processo dentário erosivo.


Assuntos
Bebidas , Esmalte Dentário , Testes de Dureza
3.
RPG rev. pos-grad ; 18(4): 253-259, Out.-Dez. 2011. tab
Artigo em Português | LILACS | ID: lil-693937

RESUMO

Este estudo avaliou a microdureza da resina composta à base de silorano (RCS) fotoativada com luz halógena (LH) e LED, seguido da exposição aos colutórios bucais Periogard, Listerine e Colgate Plax Sem Álcool. Foram confeccionados 40 espécimes da RCS Filtek P90 e divididos em 2 grupos (n = 20): Grupo LED - fotoativação com LED por 40 s (1200 mW/cm2); Grupo LH - fotoativação com LH por 40 s (600 mW/cm2). Os espécimes foram distribuídos em 4 subgrupos (n-5) de acordo com o bochecho: Subgrupo C - imersos em saliva artificial por 7 dias; Subgrupo LI - agitados no colutório Listerine 1 vez ao dia por 1 minuto durante 7 dias, em seguida, armazenados em saliva artificial; Subgrupo CP - agitados no colutório Colgate Plax Sem Álcool, seguindo o mesmo protocolo acima; Subgrupo PE - agitados no colutório Periogard, seguindo o mesmo protocolo acima. Os espécimes foram submetidos ao ensaio de microdureza no Microdurômetro digital Vickers com três endentações e carga de 50 g/ 15 s e os dados, submetidos aos testes ANOVA dois fatores (Fonte de luz e Colutório bucal) e Tukey (5%). Houve diferença significante para os fatores Fonte de luz e Colutório bucal (p = 0,00). Os valores da microdureza para o fator Fonte de luz: Grupo LED - 72,61 a; Grupo LH - 67,21 b; para o fator Colutório bucal: Subgrupo C - 79,29 a; Subgrupo PL - 75,5 a; Subgrupo PE - 66,12 b; Subgrupo LI - 58,75c. Para o fator Fonte de luz, LED apresentou dureza superior a LH. Para o fator Colutório bucal, o armazenamento em saliva artificial apresentou dureza superior em relação ao uso dos colutórios Periogard e Listerine.


This study evaluated the microhardness of silorane-based composite resin cured with halogen light and LED, followed by the use of mouthwashes: Periogard, Listerine, and Colgate Plax Without Alcohol. Forty specimens were fabricated with silorane-based composite resin Filtek P90 and divided into two groups (n = 20): Group LED - LED light curing for 40 s (1200 mW/cm2), Group HL - Halogen light curing for 40 s (600 mW/cm2). The specimens were divided into four subgroups (n-5) in accordance with the use of the mouthwash: Subgroup C - immersed in artificial saliva for 7 days; Subgroup LI - Listerine mouthwash once daily for 1 minute during 7 days, then stored in artificial saliva; Subgroup CP - Colgate Plax Without Alcohol mouthwash, following the same protocol above; Subgroup PE - Periogard mouthwash, following the same protocol above. The specimens were subjected to microhardness test on digital Microhardness Vickers with three indentations and load of 50 g/ 15 s. The data were submitted to ANOVA two factors (Light and Mouthwash) and Tukey (5%). There were significant differences for the factors Light and Mouthwash (p = 0.00). The values of microhardness for Light Factor: LED Group - to 72.61 a and Group HL - 67.21 b; for Mouthwash Factor: Subgroup C - 79.29 a; subgroup PL - to 75.5 a; subgroup EP - 66.12 b; Subgroup LI - 58.75 c. For Light Factor, LED showed hardness higher than halogen light. For Mouthwash Factor, storage in artificial saliva showed higher hardness compared to the use of Listerine and Periogard mouthwashes.

4.
Rev. odonto ciênc ; 25(1): 83-87, jan.-mar. 2010. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-874067

RESUMO

Purpose: The aim of this study was to assess the influence of topical acidulated phosphate fluoride on the surface roughness of both human enamel and different restorative materials. Methods: Resin-modified glass ionomer (Vitremer = V), microhybrid composite resin with fluoride (Tetric Ceram = T), and nanofiller composite resin without fluoride (Z350 = Z) were evaluated. Acidulated phosphate fluoride (APF, 1.23%) was applied to half of the specimens (groups VF, TF, ZF and EF). Ten intact human third molars were used to obtain enamel specimens (E). Six experimental groups (n=10) and two control groups (n=10) were formed. The mean surface roughness (Ra) of both the restorative materials and enamel, with and without fluoride, was evaluated with a profilometer. Data were analyzed with an ANOVA, Tukey's test, Student's t-test, and Dunn-Bonferroni test at the 5% significance level. Results: The mean values of surface roughness, in micrometers, were as follows: Z=0.60; TF=1.00; ZF=1.05; VF=1.18; T=2.10; V=2.70; E=16.99; and EF=21.19. Both E and EF presented significantly higher surface roughness than the other experimental groups. Conclusion: It was concluded that APF increased the surface roughness of enamel and decreased the surface roughness of both resin-modified glass-ionomer cement and microhybrid composite resin with fluoride. The surface roughness of the nanofiller composite resin was not modified by APF.


Objetivo: Este estudo avaliou a influência da aplicação tópica de flúor fosfato acidulado sobre a rugosidade do esmalte e de diferentes materiais restauradores. Metodologia: Amostras de cimento de ionômero de vidro modificado por resina (Vitremer - V), resina composta microhíbrida com flúor (Tetric Ceram - T) e resina nanopartículada sem flúor em sua composição (Z350 - Z) foram confeccionadas. Metade das amostras recebeu aplicação tópica de flúor fosfato acidulado a 1,23% (FFA) (grupos VF, TF, ZF e EF) e a outra metade não, totalizando 6 grupos experimentais (n=10). Dez terceiros molares humanos hígidos foram utilizados para confecção de amostras de esmalte (E), constituindo os grupos controles (n=10). A rugosidade média superficial (Ra) dos materiais restauradores e do esmalte, com e sem flúor, foi analisada pelo rugosímetro. Os dados foram submetidos à análise de variância, testes de Tukey, t-Student e de Dunn-Bonferroni (5 % de significância). Resultados: Os valores médios de rugosidade, em micrômetros, foram: Z=0,60; TF=1,00; ZF=1,05; VF=1,18; T=2,10; V=2,70; E=16,99 e EF=21,19. E e EF apresentaram Ra significativamente superior aos grupos experimentais. Conclusão: Concluiu-se que o FFA aumentou a rugosidade do esmalte, diminuiu a do cimento de ionômero de vidro e da resina microhíbrida com flúor e não alterou a rugosidade da resina nanoparticulada sem flúor.


Assuntos
Humanos , Resinas Compostas , Esmalte Dentário , Flúor/efeitos adversos , Cimentos de Ionômeros de Vidro , Estudos de Casos e Controles
5.
Pesqui. bras. odontopediatria clín. integr ; 7(2): 155-160, maio-ago. 2007. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-495470

RESUMO

Objetivo: Avaliar a resistência à tração entre resinas compostasde uso direto e seus reparos, utilizando-se três diferentes marcascomerciais: G I Palfique Estelite Ó (Tokuyama), G II Filtek Z350 (3MESPE) e G III Te Econon (Ivoclar Vivadent) e a utilização na interfacebase/reparo do adesivo AdperTM Single Bond 2 (3M-ESPE).Método: Foram confeccionadas 30 bases cônicas de cada marcacomercial de resina composta nas seguintes dimensões: 5mm X5mm X 3mm. Todas as bases de cada grupo foram submetidas a20000 ciclos de termociclagem (5ºC a 55ºC ± 2ºC, por 30s). Asbases de cada grupo foram divididas aleatoriamente em três subgrupos,nos quais realizou-se a combinação entre as marcascomerciais selecionadas para realização dos reparos. Armazenouseas amostras por 7 dias à 37°C em água destilada, sendo entãosubmetidas ao ensaio de tração em uma máquina de ensaiosuniversal EMIC – MEM 2000, com velocidade de 1,0mm/ min e célulade carga de 500Kgf, a qual carregou a amostra até que ocorressea fratura. Os dados obtidos (MPa) foram submetidos à Análise deVariância (ANOVA), e ao teste de Tukey (5%).Resultados: Para GI observou-se: Palfique Estelite Ó (11,22±4,00MPa), Te Econom (12,03±3,47 MPa) e Filtek Z350 (10,66±2,89 MPa),para GII foi: Palfique Estelite Ó (8,88±2,04 MPa), Te Econom(7,77±1,64 MPa) e Filtek Z350 (10,50±6,14 MPa) e para GIII osresultados foram: Palfique Estelite Ó (8,41±2,50 MPa), Te Econom(12,33±3,18 MPa) e Z350 (11,73±3,54 MPa).Conclusão: A resistência adesiva na interface de diferentesmarcas comerciais de resina composta submetidas a um reparo,mostrou semelhanças estatísticas independente da marcacomercial.


Assuntos
Resinas Compostas , Adesivos Dentinários , Materiais Dentários/análise , Resistência à Tração , Análise de Variância , Interpretação Estatística de Dados
6.
RFO UPF ; 10(1): 39-42, jan.-jun. 2005. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-438485

RESUMO

O objetivo deste estudo in vitro foi avaliar ao microscópio eletrônico de verredura (MEV) alterações na micromorfologia do esmalte de dentes permanentes jovens submetidos a três métodos de profilaxia. Foram selecionados quarenta pré-molares hígidos, divididos aleatoriamente em quatro grupos experimentais com dez dentes cada. No primeiro grupo foi utilizado o jato de bicarbonato Profident (Dabiatlante); no segundo, uma mistura de água destilada e pedra-pomes (S.S. White); no terceiro,a pasta profilática Herjos-F (Vigodent S.A.)e, por fim, no quarto não foi realizado nenhum tipo de tratamento profilático, sendo esse considerado o grupo de controle. Após a realização da profilaxia, todos os espécimes foram lavados com spray de água/ar, desidratados, montados em bases metálicas, cobertos com outro e examinados em microscópio eletrônico de carredura (Jeol, JSM-600). A análise das eletromicrografias revelou que as amostras do Grupo I apresentaram uma superficie bastante irrgular, com a presença de grânulos e ausência de ranhuras; no Grupo II a superficie do esmalte apresentou ranhuras em grande quantidade e bastante acentuadas e, no Grupo III, foram observadas ranhuras pouco acentuadas e a presença de grânulos com diâmetros variados na superficie do esmalte


Assuntos
Humanos , Masculino , Feminino , Esmalte Dentário , Profilaxia Dentária , Técnicas In Vitro , Microscopia Eletrônica de Varredura
7.
JBP rev. Ibero-am. odontopediatr. odontol. bebê ; 7(37): 291-295, maio-jun. 2004. tab, graf, CD-ROM
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-872824

RESUMO

O estudo de prevalência é um importante instrumento de diagnóstico e prevenção de patologias ou de acidentes ocorridos em uma determinada população. Neste contexto, levantou-se, epidemiologicamente, o quadro clínico de fraturas coronárias em dentes anteriores de 865 escolares de 6 a 18 anos, do município de São José dos Campos, SP, no período de agosto a outubro de 2001. Os dados foram tabulados em relação ao sexo, idade, tipo de fratura coronária, recobrimento labial e ocorrência ou não de tratamento. Os resultados foram analisados estatisticamente (teste Qui-Quadrado), sob nível de significância de 5%. Foram encontrados 90 casos de fraturas entre os sexos, o que representa 10,4% do total da amostra. Não houve diferença estatística na proporção de fraturas entre os sexos, sendo observada maior prevalência na faixa etária de 6 a 9 anos para o sexo feminino e de 7 a 10 anos para o sexo masculino. Os dentes mais acometidos foram os incisivos centrais superiores, isolados ou ambos os dentes. O tipo de fratura coronária mais comum foi o de esmalte e dentina. Verificou-se a importância de ações preventivas aos traumas em crianças pertencentes a específicas faixas etárias e condições clínicas predisponentes


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Dentição Permanente , Fraturas dos Dentes/terapia , Traumatismos Dentários/complicações , Prevenção de Acidentes , Acidentes por Quedas , Estudos Transversais
8.
J. bras. ortodon. ortop. facial ; 6(32): 156-166, mar.-abr. 2001. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-308323

RESUMO

Esta pesquisa teve o objetivo de avaliar os tamanhos dentários e as dimensöes dos arcos dentários, relativos ao Índice de Pont, e a presença de dimorfismo sexual, em uma amostra da populaçäo brasileira, caracterizada por apresentar más-oclusöes de Classe I e II de Angle. Foram utilizados para a amostra 119 modelos de pacientes leucodermas de Classe I e Classe II de Angle, dos sexos masculino e feminino, com apinhamento inferior a 3 mm. Foram realizadas medidas dos incisivos centrais e incisivos laterais superiores bem como as distâncias inter-pré-molares e inter-molares e calculados os valores previstos por Pont para essas distâncias. Os resultados das análises estatísticas revelaram uma predominância dos diâmetros dos incisivos superiores do sexo masculino nos pacientes apresentando Classe II mas näo nos de Classe I. Já as dimensöes transversais foram maiores no sexo masculino, independentemente da relaçäo molar apresentada. Além disso, verificaram-se baixas correlaçöes entre as medidas observadas e previstas, com valores sistematicamente subestimados pelo Índice de Pont, em comparaçäo aos apresentados pelos pacientes


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Arco Dental , Má Oclusão Classe I de Angle , Má Oclusão Classe II de Angle , Dente , Dente Pré-Molar , Caracteres Sexuais , Coroa do Dente/anatomia & histologia , Incisivo , Dente Molar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...